HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Meconium-stained amniotic fluid.

Abstract
Green-stained amniotic fluid, often referred to as meconium-stained amniotic fluid, is present in 5% to 20% of patients in labor and is considered an obstetric hazard. The condition has been attributed to the passage of fetal colonic content (meconium), intraamniotic bleeding with the presence of heme catabolic products, or both. The frequency of green-stained amniotic fluid increases as a function of gestational age, reaching approximately 27% in post-term gestation. Green-stained amniotic fluid during labor has been associated with fetal acidemia (umbilical artery pH <7.00), neonatal respiratory distress, and seizures as well as cerebral palsy. Hypoxia is widely considered a mechanism responsible for fetal defecation and meconium-stained amniotic fluid; however, most fetuses with meconium-stained amniotic fluid do not have fetal acidemia. Intraamniotic infection/inflammation has emerged as an important factor in meconium-stained amniotic fluid in term and preterm gestations, as patients with these conditions have a higher rate of clinical chorioamnionitis and neonatal sepsis. The precise mechanisms linking intraamniotic inflammation to green-stained amniotic fluid have not been determined, but the effects of oxidative stress in heme catabolism have been implicated. Two randomized clinical trials suggest that antibiotic administration decreases the rate of clinical chorioamnionitis in patients with meconium-stained amniotic fluid. A serious complication of meconium-stained amniotic fluid is meconium aspiration syndrome. This condition develops in 5% of cases presenting with meconium-stained amniotic fluid and is a severe complication typical of term newborns. Meconium aspiration syndrome is attributed to the mechanical and chemical effects of aspirated meconium coupled with local and systemic fetal inflammation. Routine naso/oropharyngeal suctioning and tracheal intubation in cases of meconium-stained amniotic fluid have not been shown to be beneficial and are no longer recommended in obstetrical practice. A systematic review of randomized controlled trials suggested that amnioinfusion may decrease the rate of meconium aspiration syndrome. Histologic examination of the fetal membranes for meconium has been invoked in medical legal litigation to time the occurrence of fetal injury. However, inferences have been largely based on the results of in vitro experiments, and extrapolation of such findings to the clinical setting warrants caution. Fetal defecation throughout gestation appears to be a physiologic phenomenon based on ultrasound as well as in observations in animals.
AuthorsDahiana M Gallo, Roberto Romero, Mariachiara Bosco, Francesca Gotsch, Sunil Jaiman, Eunjung Jung, Manaphat Suksai, Carlos López Ramón Y Cajal, Bo Hyun Yoon, Tinnakorn Chaiworapongsa
JournalAmerican journal of obstetrics and gynecology (Am J Obstet Gynecol) Vol. 228 Issue 5S Pg. S1158-S1178 (05 2023) ISSN: 1097-6868 [Electronic] United States
PMID37012128 (Publication Type: Systematic Review, Journal Article, Review, Research Support, N.I.H., Intramural)
CopyrightPublished by Elsevier Inc.
Chemical References
  • Heme
Topics
  • Infant, Newborn
  • Pregnancy
  • Female
  • Humans
  • Meconium Aspiration Syndrome
  • Meconium
  • Amniotic Fluid (chemistry)
  • Chorioamnionitis
  • Pregnancy Complications
  • Inflammation (complications)
  • Heme (analysis)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: