Computational fluid dynamics study of intra-arterial chemotherapy for oral cancer.

AbstractBACKGROUND:
Intra-arterial chemotherapy (IAC) for oral cancer can deliver a higher concentration of anticancer agent into a tumor-feeding artery than intravenous systemic chemotherapy. However, distribution of anticancer agent into several branches of the external carotid artery (ECA) in IAC has not demonstrated sufficient treatment efficacy. To improve the effectiveness of IAC, the flow distribution of anticancer agent into the branches of the ECA in several IAC methods was investigated using computational fluid dynamics (CFD).
METHODS:
Patient-specific three-dimensional vessel models were created from CT images of 2 patients with tongue cancer. Catheter models were combined with the vessel models. Thirty-two models were generated with varying vertical and horizontal positions of the catheter tip. With the use of a zero-dimensional resistance model of the peripheral vessel network, conventional IAC and superselective IAC were simulated in 30 and 2 models, respectively. The flow distribution of anticancer agent into the branches of the ECA was investigated in 32 models. Additionally, the blood streamline was traced from the inlet of the common carotid artery toward each outlet to examine the flow of anticancer agent in all models, and the wall shear stress of the vessel was calculated for some models.
RESULTS:
The CFD simulations could be conducted within a reasonable computational time. In several models, the anticancer agent flowed into the target artery only when the catheter tip was located below the bifurcation of the ECA and each target artery. Furthermore, the anticancer agent tended to flow into the target artery when the catheter tip was shifted toward the target artery. In all ECA branches that had flow of anticancer agent, the blood streamlines to the target arteries contacted the catheter tip. Anticancer agent flowed into only the target artery in patients' models for superselective IAC. However, high wall shear stress was observed at the target artery in one patient's model.
CONCLUSIONS:
This CFD study showed that location of the catheter tip was important in controlling the anticancer agent in conventional IAC. The distribution rate of anticancer agent into the tumor-feeding artery tended to increase when the catheter tip was placed below and toward the target artery. Although superselective IAC can reliably supply anticancer agent to the target artery, high wall shear stress at the target artery can occur, depending on vessel geometry of the patient, which may cause serious complications during the treatment.
AuthorsHiroaki Kitajima, Marie Oshima, Toshinori Iwai, Yoshihito Ohhara, Yasuharu Yajima, Kenji Mitsudo, Iwai Tohnai
JournalBiomedical engineering online (Biomed Eng Online) Vol. 16 Issue 1 Pg. 57 (May 15 2017) ISSN: 1475-925X [Electronic] England
PMID28506222 (Publication Type: Journal Article)
Chemical References
  • Antineoplastic Agents
Topics
  • Antineoplastic Agents (administration & dosage, blood, pharmacokinetics)
  • Blood Flow Velocity
  • Carotid Arteries (physiopathology)
  • Computer Simulation
  • Drug Therapy, Computer-Assisted (methods)
  • Humans
  • Hydrodynamics
  • Infusions, Intra-Arterial
  • Models, Cardiovascular
  • Rheology (methods)
  • Tongue Neoplasms (drug therapy, pathology, physiopathology)