Reducing the within-patient variability of breathing for radiotherapy delivery in conscious, unsedated cancer patients using a mechanical ventilator.

AbstractOBJECTIVE:
Variability in the breathing pattern of patients with cancer during radiotherapy requires mitigation, including enlargement of the planned treatment field, treatment gating and breathing guidance interventions. Here, we provide the first demonstration of how easy it is to mechanically ventilate patients with breast cancer while fully conscious and without sedation, and we quantify the resulting reduction in the variability of breathing.
METHODS:
15 patients were trained for mechanical ventilation. Breathing was measured and the left breast anteroposterior displacement was measured using an Osiris surface-image mapping system (Qados Ltd, Sandhurst, UK).
RESULTS:
Mechanical ventilation significantly reduced the within-breath variability of breathing frequency by 85% (p < 0.0001) and that of inflation volume by 29% (p < 0.006) when compared with their spontaneous breathing pattern. During mechanical ventilation, the mean amplitude of the left breast marker displacement was 5 ± 1 mm, the mean variability in its peak inflation position was 0.5 ± 0.1 mm and that in its trough inflation position was 0.4 ± 0.0 mm. Their mean drifts were not significantly different from 0 mm min(-1) (peak drift was -0.1 ± 0.2 mm min(-1) and trough drift was -0.3 ± 0.2 mm min(-1)). Patients had a normal resting mean systolic blood pressure (131 ± 5 mmHg) and mean heart rate [75 ± 2 beats per minute (bpm)] before mechanical ventilation. During mechanical ventilation, the mean blood pressure did not change significantly, mean heart rate fell by 2 bpm (p < 0.05) with pre-oxygenation and rose by only 4 bpm (p < 0.05) during pre-oxygenation with hypocapnia. No patients reported discomfort and all 15 patients were always willing to return to the laboratory on multiple occasions to continue the study.
CONCLUSION:
This simple technique for regularizing breathing may have important applications in radiotherapy.
ADVANCES IN KNOWLEDGE:
Variations in the breathing pattern introduce major problems in imaging and radiotherapy planning and delivery and are currently addressed to only a limited extent by asking patients to breathe to auditory or visual guidelines. We provide the first demonstration that a completely different technique, of using a mechanical ventilator to take over the patients' breathing for them, is easy for patients who are conscious and unsedated and reduces the within-patient variability of breathing. This technique has potential advantages in radiotherapy over currently used breathing guidance interventions because it does not require any active participation from or feedback to the patient and is therefore worthy of further clinical evaluation.
AuthorsMichael J Parkes, Stuart Green, Andrea M Stevens, Sophia Parveen, Rebecca Stephens, Thomas H Clutton-Brock
JournalThe British journal of radiology (Br J Radiol) Vol. 89 Issue 1062 Pg. 20150741 (Jun 2016) ISSN: 1748-880X [Electronic] England
PMID26959610 (Publication Type: Journal Article)
Topics
  • Adult
  • Aged
  • Breast (physiopathology, radiation effects)
  • Breast Neoplasms (physiopathology, radiotherapy)
  • Female
  • Humans
  • Middle Aged
  • Movement
  • Patient Positioning (methods)
  • Radiotherapy Setup Errors (prevention & control)
  • Reproducibility of Results
  • Respiration, Artificial (methods)
  • Respiratory Mechanics
  • Sensitivity and Specificity

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: