Objectives : To evaluate whether virtual partial
nephrectomy images could help surgeons identify vascular and collecting system around
tumors during actual surgery. Materials & methods : We retrospectively analyzed 36 patients who underwent robot-assisted partial
nephrectomy (RAPN) between 2016 and 2017. Virtual partial
nephrectomy images were created from preoperative CT images using computer software, and then analyzed. For analysis, blood vessels and collecting system portions within a 5-mm-thick safety margin around the
tumor were examined. During analysis, we predicted whether targeted vasculature around the
tumor would require clipping or suturing during surgery, and also whether the collecting system would require opening during resection. Surgical outcomes for virtual partial
nephrectomy analyses and actual RAPNs were compared and analyzed for sensitivity and specificity. Results : In 36 cases, 119 arteries and 100 veins were targeted on virtual partial
nephrectomy images. Arterial suturing or clipping for hemostasis showed a sensitivity and specificity of 83.3% and 84.5%, respectively. For veins, the sensitivity and specificity were 39.1% and 92.2%, respectively. Collecting system opening prediction sensitivity was 85.7%, and specificity was 65.2%. Conclusion : Virtual partial
nephrectomy imaging is useful for RAPN planning, particularly regarding arteries and the collecting system. It is hoped that techniques for visualizing veins will improve. J. Med. Invest. 69 : 237-243, August, 2022.