Biological Dose Optimization for Particle Arc Therapy Using Helium and Carbon Ions.

AbstractPURPOSE:
To present biological dose optimization for particle arc therapy using helium and carbon ions.
METHODS AND MATERIALS:
Treatment planning and optimization procedures were developed for spot-scanning hadron arc (SHArc) delivery using the RayStation treatment planning system and FRoG dose engine. The SHArc optimization algorithm is applicable for charged particle beams and determines angle dependencies for spot and energy selection with three main initiatives: (i) achieve standard clinical optimization goals and constraints for target and organs at risk (OARs), (ii) target dose robustness, and (iii) increase linear energy transfer (LET) in the target volume. Three patient cases previously treated at the Heidelberg Ion-beam Therapy Center (HIT) were selected for evaluation of conventional versus arc delivery for the two clinical particle beams (helium [4He] and carbon [12C] ions): glioblastoma, prostate adenocarcinoma, and skull-base chordoma. Biological dose and dose-averaged LET (LETd) distributions for SHArc were evaluated against conventional planning techniques (volumetric modulated arc therapy [VMAT] and 2-field intensity modulated particle therapy) applying the modified microdosimetric kinetic model with (α/β)x = 2 Gy. Clinical viability and deliverability were assessed via evaluation of plan quality, robustness, and irradiation time.
RESULTS:
For all investigated patient cases, SHArc treatment optimizations met planning goals and constraints for target coverage and OARs, exhibiting acceptable target coverage and reduced normal tissue volumes, with effective dose >10-GyRBE compared with conventional 2F planning. For carbon ions, LETd was increased in the target volume from ∼40-60 to ∼80-140 keV/µm for SHArc compared with conventional treatments. Favorable LETd distributions were possible with the SHArc approach, with maximum LETd in clinical target volume/gross tumor volume and potential reductions of high-LET regions in normal tissues and OARs. Compared with VMAT, SHArc affords substantial reductions in normal tissue dose (40%-70%).
CONCLUSIONS:
SHArc therapy offers potential treatment benefits such as increased normal tissue sparing from higher doses >10-GyRBE, enhanced target LETd, and potential reduction in high-LET components in OARs. Findings justify further development of robust SHArc treatment planning toward potential clinical translation.
AuthorsStewart Mein, Thomas Tessonnier, Benedikt Kopp, Christian Schömers, Semi Harrabi, Amir Abdollahi, Jürgen Debus, Thomas Haberer, Andrea Mairani
JournalInternational journal of radiation oncology, biology, physics (Int J Radiat Oncol Biol Phys) Vol. 114 Issue 2 Pg. 334-348 (10 01 2022) ISSN: 1879-355X [Electronic] United States
PMID35490991 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
CopyrightCopyright © 2022 Elsevier Inc. All rights reserved.
Chemical References
  • Ions
  • Helium
  • Carbon
Topics
  • Carbon (therapeutic use)
  • Helium (therapeutic use)
  • Humans
  • Ions (therapeutic use)
  • Male
  • Organs at Risk (radiation effects)
  • Proton Therapy (methods)
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted (methods)
  • Radiotherapy, Intensity-Modulated (methods)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: