We retrospectively reviewed the electronic records for patients treated with chimneys/periscopes from 1997 through 2020. Baseline characteristics, procedural details, periprocedural complications, reinterventions, and midterm outcomes were collected.
RESULTS: Fifty-eight patients (86 vessels) were treated; the median follow-up was 32 months (range, 0.03-104 months). There were 36% (n = 21) juxta-renal, 2% (n = 1) para-visceral, and 21% (n = 12) thoracoabdominal
aneurysms, and 41% (n = 24) had pararenal failure of prior
endovascular aneurysm repair (n = 17) or open repair (n = 7).
Stent configuration for the majority of the 86 vessels (n = 80; 93%) treated were chimney configuration (n = 6 periscopes; 7%). The most common
stent graft utilized was Viabahn, and 8.1% (n = 7) were reinforced with a bare
metal stent. Although the majority of the cases were elective, 36.2% (n = 21) of the cases were urgent/emergent. At the conclusion of the initial procedure, 16 of 58 patients had an
endoleak (gutter, 50% [8/16]; type Ia, 25% [4/16]; and type II, 25% [4/16]). On follow-up, 14 of 58 patients developed one or more
endoleaks, with the most common
endoleaks being a gutter
endoleak (35% [7/20]). Other
endoleaks observed included 30% (6/20) type III, 15% (3/20) type Ia, 15% (3/20) type Ib, and 5% (1/20) type II. Eleven of 58 patients underwent interventions for one or more
endoleak (gutter, 33% [5/15]; type Ib, 20% [3/15]; type II, 7% [1/15]; and type III, 40% [6/15]). Twelve of 58 patients returned to the operating room for one or more procedures during the index hospitalization (five
laparotomies, three dialysis access, three acute limb
ischemia, and four chimney/periscope interventions). Ten of 58 patients underwent angioplasty/stenting for chimney/periscope compression or occlusion during the follow-up period. Survival was 61.3% at 1 year by Kaplan-Meier analysis (75% for elective, 37% for urgent/emergent) (
aneurysm-related death, 22%). Cox hazard modeling showed that
aneurysm diameter (hazard ratio, 1.03; 95% confidence interval, 1.004-1.05; P = .02) and urgent/emergent interventions (hazard ratio, 3.6; 95% confidence interval, 1.33-9.74; P = .01) were predictors of mortality.
CONCLUSIONS: Endovascular repair of
aortic aneurysms with chimneys/periscopes is associated with poor outcomes, including limited technical success and
aneurysm exclusion, as well as high morbidity and mortality, with a high rate of reinterventions both in the immediate postoperative period and on follow-up. They should be used only when other surgical or endovascular options are not possible.