HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Concurrent identification of 11 major primary active compounds in Huangqin Qingfei Decoction by liquid chromatography tandem mass spectrometry via liquid chromatography tandem mass spectrometry.

Abstract
Huangqin Qinfei Decoction (HQD) is a traditional Chinese medicine that is administered for acute pneumonia, bronchial inflammation, acute bronchitis and acute lung infection. In this study, we used liquid chromatography linked with tandem mass spectrometry (LC-MS/MS) for the concurrent identification of 11 bioactive compounds; namely, baicalin, baicalein, wogonoside, scutellarin, wogonin, oroxylin A, geniposide, genipin, geniposidic acid, chlorogenic acid, and crocin-I, for the quality control of HQD. The evaluation was conducted on an Agilent Poroshell 120 EC-C18 (2.1mm×100mm, 2.7μm) with gradient elution in the mobile phase with 0.1% formic acid and 1mM/L ammonium acetate in water as solvent A and methanol as solvent B at a flow rate of 0.3mL/min in under 12 min. Mass spectrometric detection was conducted in the selected reaction monitoring mode utilizing electro spray ionization in the positive and negative modes. Every one of the calibration curves had good linearity with R2 >0.9992. Intra-day and inter-day accuracies for every one of the evaluated components were expressed as the relative standard deviation (RSD) from 1.72%-5.02% and 0.63%-5.99%, respectively. The recuperation of the 11 compounds that were measured at the three concentrations was within 94.05%-105.18%, with the RSD ≤ 6.26%. The use of this method was determined through the effective evaluation of 11 compounds in 5 batches of HQD. The confirmed method is precise, sensitive, and effective for identifying the contents of the chosen compounds in HQD for quality control.
AuthorsYi-Fan Zhang, Ye Lu, Juan Xiao, Ye Chen, Xin-Hong Wang
JournalPakistan journal of pharmaceutical sciences (Pak J Pharm Sci) Vol. 33 Issue 3 Pg. 1005-1013 (May 2020) ISSN: 1011-601X [Print] Pakistan
PMID33191224 (Publication Type: Journal Article)
Chemical References
  • Drugs, Chinese Herbal
Topics
  • Calibration
  • Chromatography, Liquid (standards)
  • Drugs, Chinese Herbal (analysis)
  • Reference Standards
  • Reproducibility of Results
  • Spectrometry, Mass, Electrospray Ionization (standards)
  • Tandem Mass Spectrometry (standards)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: