HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients.

AbstractPURPOSE:
Ultra-protective ventilation with low tidal volume is used in severe acute respiratory distress syndrome (ARDS) patients under extracorporeal membrane oxygenation (ECMO). However, the optimal positive end-expiratory pressure (PEEP) is unknown. The aim of our study was to assess electrical impedance tomography's (EIT) ability to choose the best PEEP for these patients.
MATERIALS AND METHODS:
A recruitment maneuver and after a decremental PEEP trial from 20 to 5 cmH20 were monitored by EIT, with lung images divided into four ventral-to-dorsal horizontal regions of interest. For each patient, three EIT-based PEEP were defined: PEEP ODCLmin (lowest pressure with the least EIT-based collapse lung [CL] and overdistension [OD]), PEEP ODCL15 (lowest pressure able to limit EIT-based collapse to less than or equal to 15% with the least overdistension) and PEEP Comp (PEEP with the highest EIT-based compliance).
RESULTS:
High PEEP levels were significantly associated with more overdistension while decreasing PEEP led to more collapsed zones. PEEP ODCL15 and PEEP Comp were in complete agreement with the reference Pulmonary PEEP (chosen according to usual respiratory clinical and ultrasound criteria), PEEP ODCLmin was in average agreement with the Pulmonary PEEP.
CONCLUSION:
EIT may be a useful real-time monitoring technique to optimize the PEEP level in severe ARDS patients under ECMO.
TAKE-HOME MESSAGE:
Ultra-protective ventilation with low tidal volume is used in severe acute respiratory distress syndrome patients under extracorporeal membrane oxygenation (ECMO), but the optimal positive end-expiratory pressure is unknown. This trial shows that electrical impedance tomography may be an interesting non-invasive bedside tool to provide real-time monitoring of PEEP impact in severe ARDS patients under ECMO. The Pulmovista® electrical impedance tomography was provided by Dräger (Lübeck, Germany) during the study period. Dräger had no role in the study design, collection, analysis and interpretation of the data, writing the article, or the decision to submit the article for publication.
AuthorsFloriane Puel, Laure Crognier, Christelle Soulé, Fanny Vardon-Bounes, Stéphanie Ruiz, Thierry Seguin, Olivier Fourcade, Vincent Minville, Jean-Marie Conil, Bernard Georges
JournalJournal of critical care (J Crit Care) Vol. 60 Pg. 38-44 (12 2020) ISSN: 1557-8615 [Electronic] United States
PMID32736198 (Publication Type: Journal Article, Observational Study)
CopyrightCopyright © 2020. Published by Elsevier Inc.
Topics
  • Electric Impedance
  • Extracorporeal Membrane Oxygenation (methods)
  • Female
  • France (epidemiology)
  • Humans
  • Intensive Care Units
  • Lung (diagnostic imaging, physiopathology)
  • Male
  • Middle Aged
  • Monitoring, Physiologic (methods)
  • Positive-Pressure Respiration (methods)
  • Prospective Studies
  • Respiratory Distress Syndrome (diagnostic imaging, epidemiology, therapy)
  • Severity of Illness Index
  • Tidal Volume
  • Tomography, X-Ray Computed (methods)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: