HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Valve hemodynamic performance and myocardial strain after implantation of a third-generation, balloon-expandable, transcatheter aortic valve.

AbstractBACKGROUND:
Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS); however, transcatheter aortic valve implantation (TAVI) may positively affect LV mechanics. Assessed herein is the performance of the SAPIEN 3 transcatheter heart valve (THV) and the effect of TAVI on LV function recovery, as assessed by global longitudinal strain (GLS).
METHODS:
A subset of patients from the SOURCE 3 registry (n = 276) from 16 European centers received SAPIEN 3 balloon-expandable THV. Echocardiography was performed at baseline, postprocedure, and at 1 year, including assessment of GLS using standard two-dimensional images, and was analyzed in a core laboratory. Paired analyses between baseline and discharge, baseline and at 1 year were conducted.
RESULTS:
Hemodynamic parameters were improved after TAVI and sustained to 1 year. At 1 year, the rate of moderate to severe paravalvular leaks (PVL), and moderate to severe mitral and tricuspid regurgitations were 1.8%, 1.7%, and 8.0%, respectively. The discharge GLS (-15.6 ± 5.1; p = 0.004; n = 149) improved significantly from baseline (-15.1 ± 4.8) following TAVI. This improvement was sustained at 1 year compared with baseline (-17.0 ± 4.6, p < 0.001; n = 100). Conversely, LV ejection fraction (LVEF) did not significantly change following TAVI (p = 0.47).
CONCLUSIONS:
Following TAVI with a third-generation THV, valve performances were good at 1 year with low PVL rate. The LV mechanics improved immediately after the procedure and were maintained at 1 year. These findings demonstrate the benefit of TAVI on LV mechanics, and suggests that GLS may be superior to LVEF in assessing this benefit. Clinicaltrial.gov number: NCT02698956.
AuthorsSara Fernandez-Santos, Alexis Théron, Philippe Pibarot, Frédéric Collart, Martine Gilard, Marina Urena, Tomas Hovorka, Philipp Kahlert, José Luis Zamorano Gomez
JournalCardiology journal (Cardiol J) Vol. 27 Issue 6 Pg. 789-796 ( 2020) ISSN: 1898-018X [Electronic] Poland
PMID31106841 (Publication Type: Journal Article)
Topics
  • Aortic Valve (diagnostic imaging, surgery)
  • Aortic Valve Stenosis (diagnosis, surgery)
  • Hemodynamics
  • Humans
  • Transcatheter Aortic Valve Replacement (adverse effects)
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: