HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Minimally Invasive Sacroiliac Joint Fusion Using a Novel Hydroxyapatite-Coated Screw: Preliminary 1-Year Clinical and Radiographic Results of a 2-Year Prospective Study.

AbstractOBJECTIVE:
Proper diagnosis and treatment of sacroiliac joint (SIJ) pain remains a clinical challenge. Dysfunction of the SIJ can produce pain in the lower back, buttocks, and extremities. Triangular titanium implants for minimally invasive surgical arthrodesis have been available for several years, with reputed high levels of success and patient satisfaction. This study reports on a novel hydroxyapatite-coated screw for surgical treatment of SIJ pain.
METHODS:
Data were prospectively collected on 32 consecutive patients who underwent minimally invasive SIJ fusion with a novel hydroxyapatite-coated screw. Clinical assessments and radiographs were collected and evaluated at 3, 6, and 12 months postoperatively.
RESULTS:
Mean (standard deviation) patient age was 55.2 ± 10.7 years, and 62.5% were female. More patients (53.1%) underwent left versus right SIJ treatment, mean operative time was 42.6 ± 20.4 minutes, and estimated blood loss did not exceed 50 mL. Overnight hospital stay was required for 84% of patients, and the remaining patients needed a 2-day stay (16%). Mean preoperative visual analog scale back and leg pain scores decreased significantly by 12 months postoperatively (P < 0.01). Mechanical stability was achieved in 93.3% (28/30) of patients, and all patients who were employed preoperatively returned to work within 3 months. Two patients who required revision surgery reported symptom improvement within 3 weeks and did not require subsequent surgery.
CONCLUSIONS:
Positive clinical outcomes are reported 1 year postoperatively after implantation of a novel implant to treat sacroiliac joint pain. Future clinical studies with larger samples are warranted to assess long-term patient outcomes.
AuthorsLouis H Rappoport, Ingrid Y Luna, Gita Joshua
JournalWorld neurosurgery (World Neurosurg) Vol. 101 Pg. 493-497 (May 2017) ISSN: 1878-8769 [Electronic] United States
PMID28216399 (Publication Type: Journal Article)
CopyrightCopyright © 2017 Elsevier Inc. All rights reserved.
Chemical References
  • Durapatite
Topics
  • Aged
  • Bone Screws (statistics & numerical data, trends)
  • Durapatite (administration & dosage)
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Minimally Invasive Surgical Procedures (methods, trends)
  • Prospective Studies
  • Sacroiliac Joint (diagnostic imaging, surgery)
  • Spinal Fusion (methods, trends)
  • Time Factors

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: