HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

[Comparative analysis of immunoglobulin free light chains quantification by Freelite™ (The Binding Site) and N Latex FLC (Siemens) methods].

Abstract
Serum immunoglobulin free light chain assay has proved to be an invaluable biological tool for diagnosis and monitoring of monoclonal gammopathies including multiple myeloma, primary amyloidosis, solitary plasmocytoma or monoclonal gammopathy of undetermined significance. Free light chain quantification, although essential, cannot be achieved by serum protein electrophoresis either because there is no monoclonal peak or because the peak is hidden in beta or alpha-globulin fraction. As for serum protein immunofixation, this major test allows the typing of the paraprotein but does not provide any quantitative evaluation. Hence, the development of free light chain assays constitutes a significant improvement in the management of these patients. In this context, we compared the results of serum free light chains quantification and of calculation of the ratio kappa/lambda, indicator of monoclonality, in forty samples performed on BN ProSpec(®) analyzer, with the two methods available on the European market. This comparative analysis provided evidence of a good correlation of results between the two methods. However, we noticed clinically significant differences in four samples. In addition, this evaluation highlighted the fact that all free light chain results must be biologically validated on the light of different criteria such as serum protein electrophoresis, serum protein immunofixation, presence of proteinuria, presence of renal failure, and additional clinical data, in order to ascertain the best interpretation for clinical use.
AuthorsNathalie Schneider, Alain Wynckel, Brigitte Kolb, Emilie Sablon, Philippe Gillery, François-Xavier Maquart
JournalAnnales de biologie clinique (Ann Biol Clin (Paris)) 2013 Jan-Feb Vol. 71 Issue 1 Pg. 13-9 ISSN: 1950-6112 [Electronic] France
Vernacular TitleÉtude comparative du dosage des chaînes légères libres d'immunoglobulines par technique Freelite™ (The Binding Site) et N Latex FLC (Siemens).
PMID23396425 (Publication Type: Comparative Study, Evaluation Study, Journal Article)
Chemical References
  • Immunoglobulin Light Chains
  • Latex
  • Reagent Kits, Diagnostic
Topics
  • Binding Sites
  • Humans
  • Immunoassay (methods)
  • Immunoglobulin Light Chains (analysis, blood, metabolism)
  • Latex
  • Monitoring, Physiologic (methods)
  • Nephelometry and Turbidimetry (methods)
  • Paraproteinemias (blood, diagnosis, immunology)
  • Prognosis
  • Quality Control
  • Reagent Kits, Diagnostic
  • Reproducibility of Results

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: