HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Comparison of intra-articular simple compression and extra-articular distal radial fractures.

AbstractBACKGROUND:
The impact of a single well-reduced or stable intra-articular fracture oriented in the sagittal plane on the outcome of internal fixation of a distal radial fracture is uncertain. We tested the hypothesis that wrist motion and function scores would not differ between patients with an extra-articular fracture and those with a single sagittal intra-articular fracture following open fracture reduction and internal fixation with use of a volar locking plate.
METHODS:
Thirty-seven patients with a single sagittal intra-articular fracture of the distal aspect of the radius and seventy-four age and sex-matched patients with an extra-articular distal radial fracture were retrospectively analyzed with use of data gathered in a cohort study of plate and screw fixation of distal radial fractures. A volar locking plate was used in all patients. The two cohorts were analyzed for differences in motion, grip strength, pain, and Gartland and Werley, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores six, twelve, and twenty-four months after surgery. Differences between the cohorts and differences within each cohort over time were determined with use of regression analysis and the likelihood ratio test.
RESULTS:
Patients with a single sagittal intra-articular fracture and those an extra-articular fracture did not differ significantly with respect to motion, grip strength, Gartland and Werley score, or DASH score at any time point. However, there was a trend toward less pronation (95% compared with 98% of that in the contralateral arm) and less grip strength (76% compared with 81% of that in the contralateral arm) at six months and toward a smaller flexion-extension arc (118° compared with 128°) at one year after surgery in patients with a single sagittal intra-articular fracture.
CONCLUSIONS:
Open reduction and volar locking plate and screw fixation of extra-articular fractures and of simple intra-articular fractures of the distal aspect of the radius are associated with comparable impairment and disability within two years of surgery.
AuthorsJ Sebastiaan Souer, David Ring, Jesse Jupiter, Stefan Matschke, Laurent Audigé, Marta Marent-Huber, LCP Distal Radius Study Group
JournalThe Journal of bone and joint surgery. American volume (J Bone Joint Surg Am) Vol. 93 Issue 22 Pg. 2093-9 (Nov 16 2011) ISSN: 1535-1386 [Electronic] United States
PMID22262381 (Publication Type: Comparative Study, Journal Article)
Topics
  • Adult
  • Aged
  • Bone Plates
  • Bone Screws
  • Cohort Studies
  • Female
  • Follow-Up Studies
  • Fracture Fixation, Internal (instrumentation, methods)
  • Fracture Healing (physiology)
  • Fractures, Compression (diagnostic imaging, surgery)
  • Humans
  • Intra-Articular Fractures (diagnostic imaging, surgery)
  • Male
  • Middle Aged
  • Radiography
  • Radius Fractures (diagnostic imaging, surgery)
  • Range of Motion, Articular (physiology)
  • Recovery of Function
  • Retrospective Studies
  • Time Factors
  • Treatment Outcome
  • Young Adult

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: