HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Extent of and reasons for nonuse of implantable cardioverter defibrillator devices in clinical practice among eligible patients with left ventricular systolic dysfunction.

AbstractBACKGROUND:
Several studies that used claims and registry data have reported that 40% to 80% of patients eligible for an implantable cardioverter defibrillator (ICD) fail to receive one in clinical practice, and the rates are especially high among women and blacks. The extent and documented reasons for nonuse of ICDs among patients with left ventricular systolic dysfunction are unknown.
METHODS AND RESULTS:
Using hospital claims and clinical data, we identified patients hospitalized with a heart failure diagnosis and left ventricular ejection fraction ≤30% between January 1, 2007, and August 30, 2007, at a tertiary-care center. Using claims data, we determined placement of an ICD or cardiac resynchronization therapy with defibrillation device at any time up to 1 year after hospitalization. Medical records for patients without an ICD were abstracted to determine reasons for nonuse. Patients with an ICD were compared with patients without an ICD and also with patients without an ICD who did not have any contraindication for an ICD as identified through chart abstraction. Of the 542 potentially eligible patients identified, 224 (41%) did not have an ICD. In the initial adjusted analysis, female sex (odds ratio=1.90; 95% CI, 1.28 to 2.81) and increasing age (odds ratio=1.07; 95% CI, 1.04 to 1.11) were associated with a higher likelihood of not having an ICD. After detailed chart review, of the 224 patients without an ICD, 117 (52%) were ineligible for the device and 38 (17%) patients refused the device, resulting in only 69 (13%) patients eligible for an ICD who failed to receive one. In this subsequent adjusted analysis, remaining factors associated with a higher likelihood of not having an ICD were absence of ventricular arrhythmias (odds ratio=4.93; 95% CI, 2.56 to 9.50), noncardiology hospital service (odds ratio=3.73; 95% CI, 1.98 to 7.04), and lack of health insurance (odds ratio=3.10; 95% CI, 1.48 to 6.46).
CONCLUSIONS:
On the basis of a detailed chart review, the true rate of ICD underuse may be substantially lower than previous estimates. In addition, after accounting for ICD eligibility criteria, patient sex and age disparities in ICD therapy were no longer present.
AuthorsNancy M Allen LaPointe, Sana M Al-Khatib, Jonathan P Piccini, Brett D Atwater, Emily Honeycutt, Kevin Thomas, Bimal R Shah, Louise O Zimmer, Gillian Sanders, Eric D Peterson
JournalCirculation. Cardiovascular quality and outcomes (Circ Cardiovasc Qual Outcomes) Vol. 4 Issue 2 Pg. 146-51 (Mar 2011) ISSN: 1941-7705 [Electronic] United States
PMID21304098 (Publication Type: Comparative Study, Journal Article, Research Support, U.S. Gov't, P.H.S.)
Topics
  • Aged
  • Arrhythmias, Cardiac (diagnosis)
  • Black People
  • Cardiac Resynchronization Therapy (statistics & numerical data)
  • Contraindications
  • Defibrillators, Implantable (statistics & numerical data)
  • Eligibility Determination
  • Female
  • Health Services Accessibility
  • Heart Failure, Systolic (ethnology, mortality, therapy)
  • Humans
  • Insurance, Health
  • Male
  • Middle Aged
  • Racial Groups
  • Registries
  • Sex Characteristics
  • Survival Rate
  • Ventricular Dysfunction, Left (ethnology, mortality, therapy)
  • White People

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: