Stent graft versus balloon angioplasty for failing dialysis-access grafts.

AbstractBACKGROUND:
The leading cause of failure of a prosthetic arteriovenous hemodialysis-access graft is venous anastomotic stenosis. Balloon angioplasty, the first-line therapy, has a tendency to lead to subsequent recoil and restenosis; however, no other therapies have yet proved to be more effective. This study was designed to compare conventional balloon angioplasty with an expanded polytetrafluoroethylene endovascular stent graft for revision of venous anastomotic stenosis in failing hemodialysis grafts.
METHODS:
We conducted a prospective, multicenter trial, randomly assigning 190 patients who were undergoing hemodialysis and who had a venous anastomotic stenosis to undergo either balloon angioplasty alone or balloon angioplasty plus placement of the stent graft. Primary end points included patency of the treatment area and patency of the entire vascular access circuit.
RESULTS:
At 6 months, the incidence of patency of the treatment area was significantly greater in the stent-graft group than in the balloon-angioplasty group (51% vs. 23%, P<0.001), as was the incidence of patency of the access circuit (38% vs. 20%, P=0.008). In addition, the incidence of freedom from subsequent interventions at 6 months was significantly greater in the stent-graft group than in the balloon-angioplasty group (32% vs. 16%, P=0.03 by the log-rank test and P=0.04 by the Wilcoxon rank-sum test). The incidence of binary restenosis at 6 months was greater in the balloon-angioplasty group than in the stent-graft group (78% vs. 28%, P<0.001). The incidences of adverse events at 6 months were equivalent in the two treatment groups, with the exception of restenosis, which occurred more frequently in the balloon-angioplasty group (P<0.001).
CONCLUSIONS:
In this study, percutaneous revision of venous anastomotic stenosis in patients with a prosthetic hemodialysis graft was improved with the use of a stent graft, which appears to provide longer-term and superior patency and freedom from repeat interventions than standard balloon angioplasty. (ClinicalTrials.gov number, NCT00678249.)
AuthorsZiv J Haskal, Scott Trerotola, Bart Dolmatch, Earl Schuman, Sanford Altman, Samuel Mietling, Scott Berman, Gordon McLennan, Clayton Trimmer, John Ross, Thomas Vesely
JournalThe New England journal of medicine (N Engl J Med) Vol. 362 Issue 6 Pg. 494-503 (Feb 11 2010) ISSN: 1533-4406 [Electronic] United States
PMID20147715 (Publication Type: Comparative Study, Journal Article, Multicenter Study, Randomized Controlled Trial, Research Support, Non-U.S. Gov't)
Copyright2010 Massachusetts Medical Society
Topics
  • Angioplasty, Balloon (adverse effects)
  • Arteriovenous Shunt, Surgical (methods)
  • Catheters, Indwelling (adverse effects)
  • Female
  • Follow-Up Studies
  • Graft Occlusion, Vascular (etiology, therapy)
  • Humans
  • Intention to Treat Analysis
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Recurrence
  • Renal Dialysis
  • Stents (adverse effects)
  • Treatment Failure
  • Vascular Patency

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: