HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

[Three-dimensional finite element study on combined proximal and distal knee extension rearrangement for recurrent patellar dislocation].

AbstractObjective:
To establish a three-dimensional finite element analysis model of the knee joint in fresh frozen cadavers, to verify the validity of the model and to simulate the stress distribution characteristics of the patellofemoral joint after combined proximal and distal knee extension rearrangement surgery for recurrent patellar dislocation.
Methods:
One male and one female fresh frozen cadavers (4 knees in total), using voluntary body donations, were used to measure the maximum pressure on the patellofemoral articular surface at each passive flexion angle (0°, 30°, 60°, 90°, 120°) of the normal knee joint and the model after combined proximal and distal knee extension rearrangement surgery for recurrent patellar dislocation with tibial tuberosity-trochlear groove distance (TT-TG) value >2.00 cm using pressure-sensitive paper, respectively. Then, the 2 freshly frozen cadavers were used to construct three-dimensional finite element models of normal knee joints and postoperative knee joints, and the maximum pressure on the patellofemoral articular surface was measured at various passive flexion angles. The maximum pressure was compared with the measurement results of the pressure-sensitive paper to verify the validity of the three-dimensional finite element model. In addition, the maximum pressure on the patellofemoral joint surface measured by three-dimensional finite element was compared between the normal knee joint and the postoperative knee joint at various passive flexion angles, so as to obtain an effective three-dimensional finite element model for the simulation study of the stress distribution characteristics of the patellofemoral joint after combined proximal and distal knee extension rearrangement surgery for recurrent patellar dislocation.
Results:
The maximum pressure on the patellofemoral joint surface measured by pressure-sensitive paper and three-dimensional finite element measurements were similar at all passive flexion angles in the normal knee joint, with a difference of -0.08-0.06 MPa; the maximum pressure on the patellofemoral joint surface measured by pressure-sensitive paper and three-dimensional finite element measurements were also similar at all passive flexion angles in the knee after combined proximal and distal knee extension rearrangement surgery, with a difference of -0.04-0.09 MPa. The maximum pressure on the patellofemoral joint surface measured by three-dimensional finite elements were also similar between the normal knee joint and the knee joint after combined proximal and distal knee extension rearrangement surgery at all passive flexion angles, with a difference of -0.50--0.03 MPa.
Conclusion:
The three-dimensional finite element model of the normal knee joint and the knee joint after combined proximal and distal knee extension rearrangement surgery can accurately and effectively quantify the change in the maximum pressure on the patellofemoral joint surface; for recurrent patellar dislocations with TT-TG value>2.00 cm, the combined proximal and distal knee extension rearrangement surgery can achieve a maximum pressure of the patellofemoral joint surface similar to that of the normal knee joint.
AuthorsGuofeng Cai, Xu Wang, Ziwen Ning, Di Jia, Song Li, En Song, Yanlin Li
JournalZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery (Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi) Vol. 36 Issue 5 Pg. 573-581 (May 15 2022) ISSN: 1002-1892 [Print] China
PMID35570631 (Publication Type: Journal Article)
Topics
  • Biomechanical Phenomena
  • Cadaver
  • Female
  • Finite Element Analysis
  • Humans
  • Knee Joint (surgery)
  • Male
  • Patella (surgery)
  • Patellar Dislocation (surgery)
  • Patellofemoral Joint (surgery)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: