Abstract | Background: Patients with severe tricuspid valve stenosis or dysfunction following degeneration of biological valve prosthesis in tricuspid position are complex, have substantial comorbidity, and very high surgical risk. Case summary: We report two cases with transcatheter tricuspid valve-in-valve implantation in patients with degenerated tricuspid bioprosthesis with transfemoral and transjugular access with Sapien 3 valve and MyVal, respectively. Discussion: In patients with high surgical risk, transcatheter tricuspid valve implantation is a good alternative. Careful consideration of optimal access site, device size, and delivery system is paramount. This case report demonstrates technically feasible and safe transcatheter valve-in-valve implantantion in tricuspid position and highlights the importance of meticulous procedure planning.
|
Authors | Rebekka Vibjerg Jensen, Jesper Khedri Jensen, Evald Høj Christiansen, Mariann Tang, Jens Cosedis Nielsen, Christian Juhl Terkelsen |
Journal | European heart journal. Case reports
(Eur Heart J Case Rep)
Vol. 6
Issue 4
Pg. ytac131
(Apr 2022)
ISSN: 2514-2119 [Electronic] England |
PMID | 35434509
(Publication Type: Case Reports)
|
Copyright | © The Author(s) 2022. Published by Oxford University Press on behalf of European Society of Cardiology. |