HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Implications for cardiac arrest coverage using straight-line versus route distance to nearest automated external defibrillator.

AbstractAIM:
Quantifying the ratio describing the difference between "true route" and "straight-line" distances from out-of-hospital cardiac arrests (OHCAs) to the closest accessible automated external defibrillator (AED) can help correct likely overestimations in AED coverage. Furthermore, we aimed to examine to what extent the closest AED based on true route distance differed from the closest AED using "straight-line".
METHODS:
OHCAs (1994-2016) and AEDs (2016) in Copenhagen, Denmark and in Toronto, Canada (2007-2015 and 2015, respectively) were identified. Three distances were calculated between OHCA and target AED: 1) the straight-line distance ("straight-line") to the closest AED, 2) the corresponding true route distance to the same AED ("true route"), and 3) the closest AED based only on true route distance ("shortest true route"). The ratio between "true route" and "straight-line" distance was calculated and differences in AED coverage (an OHCA ≤ 100 m of an accessible AED) were examined.
RESULTS:
The "straight-line" AED coverage of 100 m was 24.2% (n = 2008/8295) in Copenhagen and 6.9% (n = 964/13916) in Toronto. The corresponding "true route" distance reduced coverage to 9.5% (n = 786) and 3.8% (n = 529), respectively. The median ratio between "true route" and "straight-line" distance was 1.6 in Copenhagen and 1.4 in Toronto. In 26.1% (n = 2167) and 22.9% (n = 3181) of all Copenhagen and Toronto OHCAs respectively, the closest AED in "shortest true route" was different than the closest AED initially found by "straight-line".
CONCLUSIONS:
Straight-line distance is not an accurate measure of distance and overestimates the actual AED coverage compared to a more realistic true route distance by a factor 1.4-1.6.
AuthorsLena Karlsson, Christopher L F Sun, Christian Torp-Pedersen, Kirstine Wodschow, Annette K Ersbøll, Mads Wissenberg, Carolina Malta Hansen, Laurie J Morrison, Timothy C Y Chan, Fredrik Folke
JournalResuscitation (Resuscitation) Vol. 167 Pg. 326-335 (10 2021) ISSN: 1873-1570 [Electronic] Ireland
PMID34302928 (Publication Type: Journal Article, Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't)
CopyrightCopyright © 2021 Elsevier B.V. All rights reserved.
Topics
  • Canada
  • Cardiopulmonary Resuscitation
  • Defibrillators
  • Electric Countershock
  • Emergency Medical Services
  • Humans
  • Out-of-Hospital Cardiac Arrest (therapy)
  • Retrospective Studies

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: