Direct reduction of high-grade lumbosacral spondylolisthesis with anterior cantilever technique - surgical technique note and preliminary results.

AbstractBACKGROUNDS:
Surgical reduction for high-grade spondylolisthesis is beneficial for restoring sagittal balance and improving the biomechanical environment for arthrodesis. Compared to posterior total laminectomy and long instrumentation, anterior lumbar inter-body fusion (ALIF) is less invasive and has the biomechanical advantage of restoring the original disk height and increasing lumbar lordosis, thus improving sagittal balance. However, the application of ALIF is still limited in treating low-grade spondylolisthesis. In this study, we developed a new technique termed anterior cantilever procedure to directly reduce the slippage of high-grade lumbosacral spondylolisthesis. The purpose of our study was to investigate the surgical outcomes of the anterior cantilever procedure followed by ALIF and posterior mono-segment instrumented fixation in high-grade spondylolisthesis.
METHODS:
All patients with high-grade spondylolisthesis who underwent anterior cantilever procedure followed by anterior lumbar inter-body fusion (ALIF) and posterior mono-segment instrumented fixation between November 2006 and July 2017 were enrolled in our study. The slip percentage, Dubousset's lumbosacral angle, pelvic tilt, sacral slope, pelvic incidence, and sagittal alignment were measured pre-operatively and postoperatively at the last follow-up. Surgery time, blood loss, complications, and hospital stay were also collected and analysed.
RESULTS:
A total of 11 consecutive patients with high-grade spondylolisthesis patients were included and analysed. All of the high-grade spondylolisthesis in our series occurred at the L5-S1 level. The median age was 37 years, and the median follow-up duration was 36 months. The average slip reduction was 30% (60 to 30%, P < 0.01), and the average correction of Dubousset's lumbosacral angle was 13.8° (84.1° to 97.9°, P < 0.01). The median intra-operative blood loss was 300 mL. All patients attained improved sagittal balance after the operation and achieved solid fusion within 9 months after surgery. No incidences of implant failure, permanent neurological deficit, or pseudarthrosis were recorded at the last follow-up.
CONCLUSIONS:
Anterior cantilever procedure followed by ALIF and posterior mono-segment instrumented fixation is a valid procedure for treating high-grade spondylolisthesis. It achieved a high fusion rate, partially reduced slippage, and significantly improved lumbosacral angle, while minimizing common complications, such as pseudarthrosis, nerve traction injury, excessive soft tissue dissection, and blood loss in posterior reduction procedures. However, posterior instrumentation is still required to the structural stability in the ALIF procedure.
LEVEL OF EVIDENCE:
IV.
AuthorsKao-Chang Tu, Cheng-Min Shih, Kun-Hui Chen, Chien-Chou Pan, Fuu-Cheng Jiang, Cheng-En Hsu, Yun-Ming Wang, Cheng-Hung Lee
JournalBMC musculoskeletal disorders (BMC Musculoskelet Disord) Vol. 22 Issue 1 Pg. 559 (Jun 18 2021) ISSN: 1471-2474 [Electronic] England
PMID34144679 (Publication Type: Journal Article)
Topics
  • Adult
  • Humans
  • Lordosis
  • Lumbar Vertebrae (diagnostic imaging, surgery)
  • Lumbosacral Region (diagnostic imaging, surgery)
  • Retrospective Studies
  • Spinal Fusion (adverse effects)
  • Spondylolisthesis (diagnostic imaging, surgery)
  • Treatment Outcome