Abstract | PURPOSE: To characterize the two-dimensional parameter Bruch's membrane opening minimum rim area (BMO-MRA) in spectral domain optical coherence tomography (SD-OCT) of the optic nerve head (ONH) compared to minimum rim width (BMO-MRW) and retinal nerve fibre layer (RNFL) thickness in a large patient cohort. METHODS: Case-control, cross-sectional study of 705 eyes of 445 participants. A total of 449 eyes with glaucoma, 67 eyes with ocular hypertension and 189 healthy controls, underwent SD-OCT and confocal laser scanning tomography ( CSLT), visual field testing and clinical examination. Morphometric ONH parameters, visual field function and diagnostic power were compared. Main outcome measures were SD-OCT-derived BMO-MRA, BMO-MRW, RNFL thickness and CSLT-derived rim area (DM-RA). RESULTS: Mean ONH area was 2.11 ± 0.57 mm2 ; mean BMO area was 1.89 ± 0.45 mm2 . Correlation of mean deviation in visual field to morphometric parameters was ρ = 0.70, (p < 0.001) for RNFL thickness, ρ = 0.68 (p < 0.001) for BMO-MRA, ρ = 0.66 (p < 0.001) for BMO-MRW. These correlations were not significantly different (p > 0.05), while DM-RA correlated significantly worse (ρ = 0.55; p < 0.001). In receiver operating characteristics, the calculated area under the curve (AUC) and sensitivity at 90% specificity to differentiate glaucoma were 0.87% and 70.1% for BMO-MRA, 0.86% and 68.1% for RNFL thickness, 0.84% and 66.0% for BMO-MRW, 0.82% and 51.3% for DM-RA. CONCLUSIONS: In a heterogenous clinical cohort of glaucoma patients, all analysed SD-OCT parameters excel DM-RA of CSLT. The two-dimensional parameter BMO-MRA shows comparable levels of diagnostic power to detect glaucoma compared to established parameters BMO-MRW and RNFL thickness. Given higher comparability between ONH sizes, BMO-MRA might become an additional standard tool in SD-OCT imaging for glaucoma.
|
Authors | Philip Enders, Werner Adler, David Kiessling, Vincent Weber, Friederike Schaub, Manuel M Hermann, Thomas Dietlein, Claus Cursiefen, Ludwig M Heindl |
Journal | Acta ophthalmologica
(Acta Ophthalmol)
Vol. 97
Issue 1
Pg. 60-67
(Feb 2019)
ISSN: 1755-3768 [Electronic] England |
PMID | 29575745
(Publication Type: Comparative Study, Journal Article)
|
Copyright | © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd. |
Topics |
- Bruch Membrane
(pathology)
- Cross-Sectional Studies
- Female
- Glaucoma
(diagnosis, epidemiology, physiopathology)
- Humans
- Intraocular Pressure
(physiology)
- Male
- Middle Aged
- Optic Disk
(pathology)
- ROC Curve
- Reproducibility of Results
- Retinal Ganglion Cells
(pathology)
- Retrospective Studies
- Severity of Illness Index
- Tomography, Optical Coherence
(methods)
- Visual Fields
|