Automated PGP9.5 immunofluorescence staining: a valuable tool in the assessment of small fiber neuropathy?

AbstractBACKGROUND:
In this study we explored the possibility of automating the PGP9.5 immunofluorescence staining assay for the diagnosis of small fiber neuropathy using skin punch biopsies. The laboratory developed test (LDT) was subjected to a validation strategy as required by good laboratory practice guidelines and compared to the well-established gold standard method approved by the European Federation of Neurological Societies (EFNS). To facilitate automation, the use of thinner sections. (16 µm) was evaluated. Biopsies from previously published studies were used. The aim was to evaluate the diagnostic performance of the LDT compared to the gold standard. We focused on technical aspects to reach high-quality standardization of the PGP9.5 assay and finally evaluate its potential for use in large scale batch testing.
RESULTS:
We first studied linear nerve fiber densities in skin of healthy volunteers to establish reference ranges, and compared our LDT using the modifications to the EFNS counting rule to the gold standard in visualizing and quantifying the epidermal nerve fiber network. As the LDT requires the use of 16 µm tissue sections, a higher incidence of intra-epidermal nerve fiber fragments and a lower incidence of secondary branches were detected. Nevertheless, the LDT showed excellent concordance with the gold standard method. Next, the diagnostic performance and yield of the LDT were explored and challenged to the gold standard using skin punch biopsies of capsaicin treated subjects, and patients with diabetic polyneuropathy. The LDT reached good agreement with the gold standard in identifying small fiber neuropathy. The reduction of section thickness from 50 to 16 µm resulted in a significantly lower visualization of the three-dimensional epidermal nerve fiber network, as expected. However, the diagnostic performance of the LDT was adequate as characterized by a sensitivity and specificity of 80 and 64 %, respectively.
CONCLUSIONS:
This study, designed as a proof of principle, indicated that the LDT is an accurate, robust and automated assay, which adequately and reliably identifies patients presenting with small fiber neuropathy, and therefore has potential for use in large scale clinical studies.
AuthorsNathalie Van Acker, Michael Ragé, Ellen Sluydts, Michiel W M Knaapen, Martine De Bie, Maarten Timmers, Erik Fransen, Carla Duymelinck, Stefanie De Schepper, Praveen Anand, Theo Meert, Léon Plaghki, Patrick Cras
JournalBMC research notes (BMC Res Notes) Vol. 9 Pg. 280 (May 23 2016) ISSN: 1756-0500 [Electronic] England
PMID27215701 (Publication Type: Journal Article, Validation Study)
Chemical References
  • UCHL1 protein, human
  • Ubiquitin Thiolesterase
Topics
  • Adult
  • Fluorescent Antibody Technique
  • Humans
  • Middle Aged
  • Observer Variation
  • Small Fiber Neuropathy (diagnosis, metabolism)
  • Ubiquitin Thiolesterase (metabolism)