HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Mechanical properties of several nickel-titanium alloy wires in three-point bending tests.

Abstract
The purpose of this study was to clarify the mechanical properties of 42 brands of nickel-titanium alloy orthodontic wires from 9 manufacturers by conducting three-point bending tests under uniform testing conditions. Manufacturers included A-Company, Hoya Medical, Lancer, Ormco, Rocky Mountain, Sankin, Tomy (GAC), TP, and 3M/Unitek. Cobalt-chrome, and titanium-molybdenum alloy wires were also tested as a reference for comparison of force levels. All reported data were recorded during the unloading process to simulate the force that a wire exerts on a tooth as it is moved into the dental arch from a position of malocclusion. The following results were obtained for the nickel-titanium wires tested. (1) Among the 0.016 inch round wires tested under a maximum deflection of 1.5 mm, the difference between the smallest (Copper nickel-titanium 35) and the largest (Aline) load values was 136 g. For the 0.016 x 0.022 inch rectangular wires tested, the difference between the smallest (Copper nickel-titanium 40) and the largest (Aline) load values was 337 g. (2) The change in load between 1.5 and 0.5 mm of deflection was examined to clarify the superelastic properties of the wires tested. For the 0.016 inch wires, 17 wire brands produced a load difference of less than 100 g, and two brands produced a difference of at least 100 g (Aline and Titanal = 100 g). For the 0.016 x 0.022 inch wires, 15 brands produced a load difference of less than 100 g, and eight brands produced a difference of over 100 g. The smallest and largest load differences were 3 g (Copper nickel-titanium 35) and 200 g (Aline). (3) The majority of the samples with a smaller load difference between deflections of 1.5 mm and 0.5 mm in the unloading process were found among super-elastic wires, while samples with a larger load difference were predominantly found among work-hardened wires. Compared with cobalt-chrome and TMA wires, nickel-titanium alloy wires exert significantly less force. However, the amount of force varies greatly from brand to brand. Consequently, when using nickel-titanium alloy wires, brands must be selected carefully by taking into consideration the severity of the malocclusion and the stage of orthodontic treatment in each case. It is the intent of this study to offer clinicians an unbiased guide for the selection of appropriate nickel-titanium alloy wires.
AuthorsH Nakano, K Satoh, R Norris, T Jin, T Kamegai, F Ishikawa, H Katsura
JournalAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics (Am J Orthod Dentofacial Orthop) Vol. 115 Issue 4 Pg. 390-5 (Apr 1999) ISSN: 0889-5406 [Print] United States
PMID10194282 (Publication Type: Comparative Study, Journal Article)
Chemical References
  • Dental Alloys
  • titanium nickelide
  • Nickel
  • Titanium
Topics
  • Dental Alloys
  • Dental Stress Analysis
  • Elasticity
  • Humans
  • Materials Testing
  • Mechanics
  • Nickel
  • Orthodontic Wires
  • Titanium

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: